Skip to main content

This page is currently under construction……

Current Instruments


*Measurement Programs/Instrumentation Maintained on Site by the CERES Radiation And Validation Experiment (CRAVE) Team

VADEQ Instrumentation
PANDORA
BSRN Site LRC-49 *
PurpleAir PA-II-SD Air Quality Sensor
NASA Micro-Pulse Lidar Network*
NASA Aerosol Robotic Network (AERONET)*

Historical Instruments

A listing of instruments previously present at the CAPABLE Site.

Pandora Instrument

Instrument

Response

Parameter

Precision

Uncertainty

Range

Resolution

Pandora

~2min

Total Column O3, NO2, HCHO, SO2, H2O, BrO

0.01 DU

0.1 DU

 

 


2009-2010 Penn State CAPABLE Instrument SuiteDownload the PDF Document

ASSIST instrument (Summers 2009 & 2010)

Instrument

Response

Parameter

Precision

Uncertainty

Range

Resolution

ASSIST
(Hampton University)

~75s

Temperature, Water mixing ratio, Cloud Fraction

 

 

0-50km

variable with altitude

Lidar instrumentation (Summers 2009 & 2010)

Instrument

Response

Parameter

Precision

Uncertainty

Range

Resolution

Leosphere scanning wind lidar

5min

1.54 µm backscatter

 

Wind spd 0.3
m/s

0.1-5 km

50 m

Lidar instrumentation (Summer 2010)

Instrument

Response

Parameter

Precision

Uncertainty

Range

Resolution

Compact Aerosol Lidar (LaRC)

2s

532 and 1062 nm backscatter

1×10-8
(m-sr)-1

Range Dep.

0.5-20 km

30 m

 

Virginia Department of Environment Quality in-situ instrumentation

Instrument

Response

Parameter

Precision

Uncertainty

Thermo Scientific 42C (Molybdenum converter)
(VADEQ)

60 s

NO and NOx

50 pptv

3%

Teledyne API 200EU w/ photolytic converter
(EPA) PI-Szykman

20 s

NO2

50 pptv

 

Thermo Scientific 49C (VADEQ)

20 s

O3

1 ppbv

4%

Thermo Scientific 48i (VADEQ)

60 s

CO

40 ppbv

5%

Thermo Scientific 43i (VADEQ)

80 s

SO2

0.2 ppbv

5%

Thermo Scientific 1400AB TEOM (VADEQ)

600 s

PM2.5 (continuous)

µg/m3

1 3%

Thermo Scientific Partisol Plus 2025 (VADEQ)

24 hr

PM2.5 (filter-based FRM)- 1/3 days

 

 

Pandora capabilities

Instrument

Response

Parameter

Precision

Uncertainty

Range

Resolution

Pandora

~2min

Total Column O3, NO2, HCHO, SO2, H2O, BrO

0.01 DU

0.1 DU

 

 

BSRN-LRC-49
Large area view.
Latitude: 37.1038
Longitude: -76.3872
Elevation: 3 m Above sea level
Scenes: urban, marsh, bay, river and farm.

Legend

  • The inner red circle is a 20km CERES foot print centered on the BSRN-LRC site.
  • The pink circle represents a possible tangential 20km foot print.
  • The middle red circle represents the area in which a 20km foot print could fall and still see the site.
  • Yellow is a sample 40 deg off nadir foot print.
  • The outer red circle is the region which would be seen by a possible 40 deg off nadir foot print.
The BSRN-LRC sun tracker at the NASA Langley Research Center on a snowy day (02/20/2015) The BSRN-LRC sun tracker at the NASA Langley Research Center on a snowy day (02/20/2015)
CAPABLE-BSRN Google Site Location Image

PurpleAir PA-II-SD Air Quality Sensor
Laser Particle Counters
Type (2) PMS5003
Range of measurement 0.3, 0.5, 1.0, 2.5, 5.0, & 10 μm
Counting efficiency 50% at 0.3μm & 98% at ≥0.5μm
Effective range
(PM2.5 standard)*
0 to 500 μg/m³
Maximum range (PM2.5 standard)* ≥1000 μg/m³
Maximum consistency error (PM2.5 standard) ±10% at 100 to 500μg/m³ & ±10μg/m³ at 0 to 100μg/m³
Standard Volume 0.1 Litre
Single response time ≤1 second
Total response time ≤10 seconds
Pressure, Temperature, & Humidity Sensor
Type BME280
Temperature range -40°F to 185°F (-40°C to 85°C)
Pressure range 300 to 1100 hPa
Humidity Response time (τ63%): 1 s
Accuracy tolerance: ±3% RH
Hysteresis: ≤2% RH
+ Access CAPABLE Site Purple Air Sensor Realtime


PurpleAir PA-II-SD Air Quality Sensor
Laser Particle Counters
Type (2) PMS5003
Range of measurement 0.3, 0.5, 1.0, 2.5, 5.0, & 10 μm
Counting efficiency 50% at 0.3μm & 98% at ≥0.5μm
Effective range
(PM2.5 standard)*
0 to 500 μg/m³
Maximum range (PM2.5 standard)* ≥1000 μg/m³
Maximum consistency error (PM2.5 standard) ±10% at 100 to 500μg/m³ & ±10μg/m³ at 0 to 100μg/m³
Standard Volume 0.1 Litre
Single response time ≤1 second
Total response time ≤10 seconds
Pressure, Temperature, & Humidity Sensor
Type BME280
Temperature range -40°F to 185°F (-40°C to 85°C)
Pressure range 300 to 1100 hPa
Humidity Response time (τ63%): 1 s
Accuracy tolerance: ±3% RH
Hysteresis: ≤2% RH
+ Access CAPABLE Site Purple Air Sensor Realtime


Pandora capabilities

Instrument

Response

Parameter

Precision

Uncertainty

Range

Resolution

Pandora

~2min

Total Column O3, NO2, HCHO, SO2, H2O, BrO

0.01 DU

0.1 DU

 

 

Virginia Department of Environment Quality in-situ instrumentation

Instrument

Response

Parameter

Precision

Uncertainty

Thermo Scientific 42C (Molybdenum converter)
(VADEQ)

60 s

NO and NOx

50 pptv

3%

Teledyne API 200EU w/ photolytic converter
(EPA) PI-Szykman

20 s

NO2

50 pptv

 

Thermo Scientific 49C (VADEQ)

20 s

O3

1 ppbv

4%

Thermo Scientific 48i (VADEQ)

60 s

CO

40 ppbv

5%

Thermo Scientific 43i (VADEQ)

80 s

SO2

0.2 ppbv

5%

Thermo Scientific 1400AB TEOM (VADEQ)

600 s

PM2.5 (continuous)

µg/m3

1 3%

Thermo Scientific Partisol Plus 2025 (VADEQ)

24 hr

PM2.5 (filter-based FRM)- 1/3 days

 

 

BSRN-LRC-49
Large area view.
Latitude: 37.1038
Longitude: -76.3872
Elevation: 3 m Above sea level
Scenes: urban, marsh, bay, river and farm.

Legend

  • The inner red circle is a 20km CERES foot print centered on the BSRN-LRC site.
  • The pink circle represents a possible tangential 20km foot print.
  • The middle red circle represents the area in which a 20km foot print could fall and still see the site.
  • Yellow is a sample 40 deg off nadir foot print.
  • The outer red circle is the region which would be seen by a possible 40 deg off nadir foot print.
The BSRN-LRC sun tracker at the NASA Langley Research Center on a snowy day (02/20/2015) The BSRN-LRC sun tracker at the NASA Langley Research Center on a snowy day (02/20/2015)
CAPABLE-BSRN Google Site Location Image